Brainstorm Electronics DXD-16 Universal Clock

A PTP Grandmaster,GPS capable, merged with a precision reference generator - 4 independent PTP ports - 16 user-definable BNC outputs - generates up to 6 different references simultaneously

A PTP Grandmaster,GPS capable, merged with a precision Reference Generator. DXD-16 Universal Clock combines PTP, GPS and legacy Sync to keep traditional Audio/ Video equipment and the IP network in perfect sync, making the DXD truly Universal

Part No:
DXD-16
1 In Stock
£8,710.00 £7,258.33
Did you find this item priced lower than £7,258.33 somewhere else? Yes

The DXD series from Brainstorm is designed to ease the transition to IP. The agship model DXD-16 is a PTP Grandmaster clock, GPS capable receiver and a multi-format legacy reference generator. While working in a PTP environment, the DXD-16 keeps legacy equipment perfectly synchronized with the IP infrastructure, or vice-versa.

IEEE 1588 Network Sync

Barinstorm’s DXD-16 can be either a PTP Grandmaster, slave or Boundary Clock. PTP (Precision Time Protocol), defined in IEEE 1588, has been broadly adopted by manufacturers as a network synchronizing standard, which means that the DXD-16 can work in a number of systems. PTP profiles supported by the DXD-16 include AES67 and SMPTE 2059.
As a Boundary Clock, the DXD-16 can be a slave to a Grandmaster on one of its attached networks, synchronize its internal clocks to that Grandmaster, and distribute the same Grandmaster time in its role as PTP master to the remaining attached networks. Alternatively it can itself fulfill the function of Grandmaster and be PTP master on all attached networks.
Four Gigabit Ethernet ports (RJ45) are available on the DXD-16. The different ports can be used independently or as primary and secondary pairs. Each network connector supports an electrically and logically independent network, with the DXD-16 acting as a PTP timing bridge. The DXD-16 is not a network switch, and for security reasons, no information flows from any network port to any other.

Customize Your Units with Universal Outputs
6 independent sync pulses and clocks are generated simultaneously by the DXD-16 and are routed to the 16 BNC universal outputs. Universal Outputs offer great flexibility compared to dedicated outputs as they can be configured for any of the generated legacy reference signals. This includes all standard SD and HD video sync formats (Black Burst and HD tri-level sync), word clock and AES-3id (at rates from 32 to 384 KHz, plus all the necessary pull-up/down, including 24:25 conversions, even VSO) and 10MHz.

Accurate and Versatile Clock Generator
A high-accuracy internal crystal oscillator (TCXO) provides a very stable frequency reference (+/- 1ppm). An optional oven-controlled oscillator (OCXO) can be installed. External legacy signals can also be used as reference, such as Word Clock, AES, Video Sync (SD & HD) or a 10MHz tone. The generated outputs have extremely low jitter. The output rates are independent from the reference rate which means that any rate can be extracted from any reference such as 59.97 from 25FPS for example.

DXD as a PTP Slave or PTP Grandmaster

  • It has the capability of being a PTP slave or a PTP Grandmaster and gives the operator exceptional flexibility:
  • As a stand-alone Master locked to its internal oscillator or GPS, it will provide sync to the network via PTP ports and to the legacy equipment via the The Brainstorm Unique Universal Outputs, simultaneously.
  • As a PTP master, the DXD can lock to an external sync source such as 10 MHz sine wave, Word Clock, AES or any standard Video Sync so the IP network locks to the existing sync sources.
  • As a PTP slave, it can generate legacy sync to keep the legacy equipment locked to the network.

GNSS / GPS
A GPS receiver can be installed in either unit. GPS not only provides an extremely accurate timing source, it also enables DXD’s in remote locations to be locked and in phase with one another. Additionally, with the GPS option, the DXD will have a higher priority as a PTP Grandmaster.

Auto Fail-over
When using an external reference, a second source can be connected as fallback in case of failure. If the external reference becomes unusable, the DXD-16 continues generating, locked either to the alternate source or to the internal oscillator and re-locks to the reference when it reappears. These transitions occur smoothly and gradually with no sync shock to the system.

Power Redundancy
An internal 100-240 VAC power supply is provided as is a DC input for an external 12VDC source. The unit can operate with either of these power sources and either can act as a back-up for the other with auto switch-over in the event of a failure.

Battery Backup
The internal time-of-day clock is battery backed-up to keep it running while power is off.

Alarm & Remote
GPIO inputs (3) and outputs (3) are included.
All functions and settings can be monitored and altered via a web browser.
Here you can create the content that will be used within the module.

Remote Control – Coming Soon

Embedded web server. The DXD is accessed with a browser

  • Monitor the unit
  • Change settings
  • Upload firmware

Web page header includes:

  • Device info (name, serial no…)
  • REF info,
  • LOCK status
  • System Time (TOD)
  • GPS status
  • Unit is monitored via the Status page
  • Settings are changed via Configuration pages 
     

 

  • PTP Grandmaster
  • 4 independent Ethernet ports
  • Synchronizes to a PTP network, a GPS clock or a legacy reference
  • 6 legacy reference generators
  • 16 user-definable BNC outputs (WC, AES, VID SYNC or 10MHz)
  • 2 user-definable external reference BNC inputs with failover for redundancy
  • Remote control via web browser
  • Multiple options: GPS receiver, OCXO, Time Code

Options Available:

  • OCXO (hardware): An oven-controlled-oscillator (OCXO) is available as an option, providing greater long-term time and TOD accuracy (+/-10ppb, which is less than +/-10 frames per year). The greater ac- curacy is also useful in GPS systems where extended GPS dropouts may be expected.
  • GNSS/GPS Receiver (hardware): Instead of relying on an external receiver, an internal GNSS/GPS receiver can be installed. This option includes an SMA antenna input connector. (Antenna not included.)
  • SDI (hardware): This option includes 2 BNC connectors: IN and LOOP THRU. Video sync can be extracted from the SDI input and used as a reference. With the time code option, time code from the SDI input can be read and used as a source for the time code generator. The SDI Loop Thru signal can be either buffered or buffered and re-clocked.
  • Time Code (firmware): Multiple time code streams can be generated simultaneously and routed to the BNC universal outputs and the 2 balanced time code outputs (DB25). Time code can be set by the user or derived from external sources with adjustable offset: LTC, VITC, GPS (TOD) or SDI (option).
More Information
Specification

Reference Generator

  • Generates simultaneously 6 different rates in any of these formats:
  • Word clock - rates from 32 to 3
    84 KHz
  • AES - rates from 32 to 96 KHz
  • Video sync:
    - NTSC/PAL black burst:
    525/29.97/30i
    625/23.98/24/25i
    - HD tri-level sync:
    720/23.98/24/25/29.97/30/50/59.94/60P
    1080/25/29.97/30i
    1080/23.98/24/25/29.97/30sF
    1080/23.98/24/25/29.97/30/50/59.94/60p  
  • 10 MHz

PTP

  • 4 independent Gigabit Ethernet port (RJ-45 connector)
  • Configurable as a Grandmaster slave (follower) or Boundry clock
  • Complies with IEEE-1588 V2 - options are available for V1 & AVB
  • Unicasr/Multicast operation 

Universal Outputs 

  • 16 outputs - in 6 different groups
  • BNC - 75 Ω
  • Output signal: any of the generated legacy references

Oscillators

  • TCXO: +/- 1 ppm
  • OCXO: +/- 10 ppb (option)


External Sync Sources

  • GPS (option)
  • Word Clock
  • AES
  • Video Sync (Black Burst or HD tri-level sync)
  • 10 MHz
  • PTP

Universal Inputs

  • 2 BNC input connectors w/ 75Ω termination switch
  • Signal type: Word Clock, AES, Video Sync, 10 MHz 

GNSS/GPS Internal Reciever (Option) 

  • The DXD-16 can be fitted with an Internal GNSS/GPS receiver.
  • The option includes an SMA antenna input connector. An antenna is required (not included)

Remote Control

  •  Web browser: 3 GPIO inputs (DB-25)

Alarm

  •  3 GPIO outputs (DB-25)

Battery backup

  •  An on-board battery keeps the internal time-of-day clock running while power is off

Presets

  •  10 presets can be programmed for quick recall

Display

  •  2.4" TFT LCD - 240 x 320 resolution

 Power

  • AC: 100-240 VAC - Internal power supply with IEC inlet
  • DC: 12 VDC @ 5A - 4-pin circular input connector for external DC power source
  • Dual power sources with auto switch-over in case of failure for redundancy

Dimensions (w x d x h)  

  • 19 x 1.75 x 8 in